Products
Products
Products
Products
Products

HC-Series – High-Density Riser Rated Tray Cables

Installation zone RECOMMENDATION
1
1
1
1
  • Designed for installation in an underground duct for data transmission between nodes or hubs
  • Cable can also be routed vertically inside buildings
  • Ideal for high-density network backbone installations

Features

  • Rugged tight-buffered fiber unit construction
  • Cable materials are Indoor/Outdoor: UV, fungus, and water resistant
  • The high-density breakout cables offer a >20% reduction in diameter and a >20% reduction in weight relative to conventional loose-tube cables, allowing for greater fiber density and cable packing within a duct
  • Meets all applicable standards for Impact & Crush Resistance (CSA C22.2 No. 230)
  • UL listed in accordance with NEC 770.179(b) for use in vertical runs in building risers or from floor to floor
  • Core-Locked® outer jacket design for installation survivability
  • Helically stranded core for greater flexibility and mechanical protection of the optical fibers
  • Cable offers a cost savings by eliminating the need to splice outdoor cable at building entrance
  • Cable can be terminated with 900µm fanout kit
  • Construction options available for direct termination of tight-buffered fiber units to MPO/MTP connectors
  • Suitable for direct pulling with wire mesh grips
  • Oil resistance for use in industrial applications (J-Jacket)
  • J-Jacket is UV, fungus, oil, and moisture resistant

Characteristics

Characteristic PVC Outer Jacket Low-Temperature PVC Outer Jacket
Operating Temp -40°C to +85°C -50°C to +75°C
Storage Temp -55°C to +85°C -55°C to +80°C
Install Temp -10°C to +60°C -20°C to +60°C
Flame Retardancy UL listed type OFNR (UL 1666) UL listed type OFNR (UL 1666)
Crush Resist 1800 N/cm 1,800 N/cm
Flex Resist 2000 cycles 2,000 cycles
Jacket Type D J

Standards

OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:

  • UL 1666
  • ICEA-S-104-696
  • ICEA-S-83-596
  • TIA-568
  • TIA-598

Specifications

Tensile Load Minimum Bend Radius
Fiber Count Part Number Spec Sheet Diameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
24 HC024D***C*R Download Spec Sheet 7.6
(0.30)
75.0
(50.0)
2,700
(600)
600
(135)
11.4
(4.5)
7.6
(3.0)
48 HC048D***C*R Download Spec Sheet 7.6
(0.30)
75.0
(50.0)
2,700
(600)
600
(135)
11.4
(4.5)
7.6
(3.0)
72 HC072D***C*R Download Spec Sheet 9.0
(0.35)
97.0
(65.0)
2,700
(600)
600
(135)
13.5
(5.3)
9.0
(3.5)
96 HC096D***C*R Download Spec Sheet 10.3
(0.41)
116.0
(78.0)
2,700
(600)
600
(135)
15.5
(6.1)
10.3
(4.1)
120 HC120D***C*R Download Spec Sheet 11.4
(0.45)
141.0
(95.0)
2,700
(600)
600
(135)
17.1
(6.7)
11.4
(4.5)
144 HC144D***C*R Download Spec Sheet 11.7
(0.46)
152.0
(102.0)
2,700
(600)
600
(135)
17.6
(6.9)
11.7
(4.6)
168 HC168D***C*R Download Spec Sheet 11.7
(0.46)
152.0
(102.0)
2,700
(600)
600
(135)
17.6
(6.9)
11.7
(4.6)
192 HC192D***C*R Download Spec Sheet 12.9
(0.51)
179.0
(120.0)
2,700
(600)
600
(135)
19.4
(7.6)
12.9
(5.1)
216 HC216D***C*R Download Spec Sheet 12.9
(0.51)
179.0
(120.0)
2,700
(600)
600
(135)
19.4
(7.6)
12.9
(5.1)
288 HC288D***C*R Download Spec Sheet 15.0
(0.59)
226.0
(152.0)
2,700
(600)
600
(135)
22.8
(9.0)
15.0
(5.9)
img
Talk to a knowledgeable OCC Expert that can find or customize a product to fit your specifications. 800-622-7711