B-Series Breakout – Riser Rated Tray Cables

Installation zone RECOMMENDATION
1
1
1
1
  • Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary
  • Typical industrial uses are factory automation, power generation and other utilities, oil and gas refining, and surface mining
  • Easiest cable to install where direct termination of the subcable to a connector and a direct run to panels and equipment are desired
  • Ideal for locations requiring low-temperature performance along with a flame rating

Features

  • Fiber Optic tray Cable: Suitable for use in cable trays
  • Individual fibers and strength members protected in a subcable configuration
  • Most rugged cable design with individual subcables for routing to diverse intelligent devices with direct connector termination at each device
  • Meets all applicable standards for Impact & Crush Resistance (CSA C22.2 No. 230)
  • Fibers may be directly terminated at factory devices or central locations using connectors with no further protection required
  • J-Jacket is UV, fungus and moisture resistant
  • Designed for indoor/outdoor installations, including cable trays
  • 2 to 72 fiber counts are available with 2.0mm or 2.5mm subcables
  • Low-temperature PVC outer jacket (J-Jacket) provides excellent performance and flexibility at low temperatures
  • Wide operating temperature range of -50°C to +75°C
  • Core-locked® jacket prevents cable from flattening and the jacket from wrinkling in tight bends:
    • Permits pulling with direct attachment of wire mesh grip; not need to access inner aramid strength members
    • Improved crush and tear resistance
    • Contains 25% more material than conventional jackets
  • High crush and tensile load ratings compared to similar tray service fiber optic cables
  • Oil resistant for use in industrial applications (J-Jacket)
  • UL listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
  • Designed to exceed the flammability requirements of Chapter 8 of IEEE 383

Characteristics

Characteristic PVC Outer Jacket Low-Temperature PVC Outer Jacket Indoor/Outdoor Zero Halogen Outer Jacket
Operating Temp -40°C to +85°C -50°C to +75°C -40°C to +70°C
Storage Temp -55°C to +85°C -55°C to +85°C -40°C to +85°C
Install Temp -10°C to +60°C -30°C to +60°C -20°C to +60°C
Flame Retardancy UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) UL listed type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Crush Resist 2200 N/cm 2200 N/cm 2200 N/cm
Impact Resist 1500 impacts 1500 impacts 1500 impacts
Flex Resist 2000 cycles 2000 cycles 2000 cycles
Jacket Type D J Z

* 2.0mm Subcables = BE; 2.5mm Subcables = BX

Standards

OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:

  • UL 1666
  • CSA C22.2 No. 232
  • CSA C22.2 No. 230
  • GR-409-CORE
  • ICEA-S-104-696
  • ICEA-S-83-596
  • TIA-568
  • TIA-598

Specifications

with 2.5mm subcables

Tensile Load Minimum Bend Radius
Fiber Count Part Number Spec Sheet Diameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
2 BX002J***9KR Download Spec Sheet 7.0
(0.28)
41.0
(28.0)
1,200
(270)
500
(110)
10.5
(4.1)
7.0
(2.8)
4 BX004J***9KR Download Spec Sheet 8.3
(0.33)
68.0
(46.0)
2,000
(450)
800
(180)
12.5
(4.9)
8.3
(3.3)
6 BX006J***9KR Download Spec Sheet 9.6
(0.38)
88.0
(59.0)
3,000
(670)
1,200
(270)
14.4
(5.7)
9.6
(3.8)
8 BX008J***9KR Download Spec Sheet 11.6
(0.46)
133.0
(89.0)
4,000
(900)
1,700
(380)
17.4
(6.9)
11.6
(4.6)
12 BX012J***9KR Download Spec Sheet 14.1
(0.56)
159.0
(107.0)
6,000
(1,350)
2,500
(560)
21.2
(8.3)
14.1
(5.6)
18 BX018J***9KR Download Spec Sheet 15.3
(0.60)
226.0
(152.0)
8,000
(1,800)
3,500
(790)
23.0
(9.1)
15.3
(6.0)
24 BX024J***9KR Download Spec Sheet 17.6
(0.69)
292.0
(196.0)
10,000
(2,250)
3,800
(850)
26.4
(10.4)
17.6
(6.9)
36 BX036J***9KR Download Spec Sheet 20.9
(0.82)
375.0
(252.0)
14,000
(3,150)
6,000
(1,350)
31.4
(12.4)
20.9
(8.2)
48 BX048J***9KR Download Spec Sheet 24.2
(0.95)
501.0
(336.0)
18,000
(4,050)
7,500
(1,690)
36.3
(14.3)
24.2
(9.5)
60 BX060J***9KR Download Spec Sheet 26.4
(1.04)
604.0
(406.0)
22,000
(4,950)
8,800
(1,980)
39.6
(15.6)
26.4
(10.4)
72 BX072J***9KR Download Spec Sheet 28.9
(1.14)
768.0
(516.0)
26,000
(5,845)
11,000
(2,470)
43.4
(17.1)
28.9
(11.4)

with 2.0mm subcables

Tensile Load Minimum Bend Radius
Fiber Count Part Number Spec Sheet Diameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
2 BE002J***9KR Download Spec Sheet 6.0
(0.24)
40.0
(27.0)
800
(180)
200
(40)
9.0
(3.5)
6.0
(2.4)
4 BE004J***9KR Download Spec Sheet 6.9
(0.27)
52.0
(35.0)
1,600
(360)
400
(90)
10.4
(4.1)
6.9
(2.7)
6 BE006J***9KR Download Spec Sheet 8.1
(0.32)
67.0
(45.0)
2,400
(560)
600
(130)
12.2
(4.8)
8.1
(3.2)
8 BE008J***9KR Download Spec Sheet 9.4
(0.37)
88.0
(59.0)
3,200
(720)
800
(180)
14.1
(5.6)
9.4
(3.7)
12 BE012J***9KR Download Spec Sheet 10.9
(0.43)
108.0
(73.0)
4,800
(1,000)
1,200
(270)
16.4
(6.5)
10.9
(4.3)
18 BE018J***9KR Download Spec Sheet 12.6
(0.50)
156.0
(105.0)
6,000
(1,350)
1,500
(340)
18.9
(7.4)
12.6
(5.0)
24 BE024J***9KR Download Spec Sheet 14.7
(0.58)
218.0
(146.0)
7,200
(1,600)
1,800
(400)
22.1
(8.7)
14.7
(5.8)
36 BE036J***9KR Download Spec Sheet 16.8
(0.66)
266.0
(179.0)
9,600
(2,100)
2,400
(540)
25.2
(9.9)
16.8
(6.6)
48 BE048J***9KR Download Spec Sheet 20.1
(0.79)
387.0
(260.0)
12,000
(2,700)
3,000
(680)
30.1
(11.9)
20.1
(7.9)
60 BE060J***9KR Download Spec Sheet 16.8
(0.66)
299.0
(201.0)
15,000
(3,400)
3,750
(850)
25.2
(9.9)
16.8
(6.6)
72 BE072J***9KR Download Spec Sheet 26.0
(1.02)
652.0
(438.0)
16,800
(3,800)
4,200
(900)
39.0
(15.4)
26.0
(10.2)