Characteristic | 6 Fiber Subunits | 12 Fiber Subunits |
---|---|---|
Operating Temp | -40°C to +85°C | -40°C to +85°C |
Storage Temp | -55°C to +85°C | -55°C to +85°C |
Install Temp | -10°C to +60°C | -10°C to +60°C |
Flame Retardancy | UL listed OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) | UL listed OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) |
Crush Resist | 1800 N/cm | 1800 N/cm |
Impact Resist | 1500 impacts | 1500 impacts |
Flex Resist | 2000 cycles | 2000 cycles |
Jacket Type | D | D |
OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements od the following standards:
Tensile Load | Minimum Bend Radius | ||||||||
---|---|---|---|---|---|---|---|---|---|
Fiber Count | Part Number | Part Number Configurator | Diameter mm (in) |
Weight kg/km (lbs/1,000ft) |
Installation N (lbs) |
Operation N (lbs) |
Installation cm (in) |
Longer Term cm (in) |
|
18 | GB018D***9KRF1 |
18.5 (0.73) |
332.0 (223.0) |
4,700 (1,060) |
1,800 (400) |
27.8 (10.9) |
18.5 (7.3) |
||
24 | GB024D***9KRF1 |
18.5 (0.73) |
332.0 (223.0) |
5,600 (1,260) |
1,900 (420) |
27.8 (10.9) |
18.5 (7.3) |
||
30 | GB030D***9KRF1 |
19.4 (0.76) |
368.0 (247.0) |
7,500 (1,690) |
2,400 (540) |
29.1 (11.5) |
19.4 (7.6) |
||
36 | GB036D***9KRF1 |
21.1 (0.83) |
436.0 (293.0) |
8,900 (2,000) |
2,850 (640) |
31.7 (12.5) |
21.1 (8.3) |
Tensile Load | Minimum Bend Radius | ||||||||
---|---|---|---|---|---|---|---|---|---|
Fiber Count | Part Number | Part Number Configurator | Diameter mm (in) |
Weight kg/km (lbs/1,000ft) |
Installation N (lbs) |
Operation N (lbs) |
Installation cm (in) |
Longer Term cm (in) |
|
24 | GX024D***9KRF1 |
20.8 (0.82) |
410.0 (276.0) |
4,600 (1,030) |
1,500 (340) |
31.2 (12.3) |
20.8 (8.2) |
||
36 | GX036D***9KRF1 |
20.8 (0.82) |
410.0 (276.0) |
5,900 (1,330) |
1,050 (440) |
31.2 (12.3) |
20.8 (8.2) |
||
48 | GX048D***9KRF1 |
20.8 (0.82) |
410.0 (276.0) |
7,200 (1,620) |
2,400 (540) |
31.2 (12.3) |
20.8 (8.2) |
Please Login Here to access additional documents.