DX-Series Distribution – Chemical Resistant – Aluminum Interlocking Armor (ILA) – Plenum Rated Cables

Installation zone RECOMMENDATION
1
1
1
1
  • Ideal for industrial and other installations requiring a metallic conduit
  • Interlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs

Applications

  • Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces
  • Ideal configuration for a single termination point requiring multiple fibers
  • Aluminum interlocking armor with fluoropolymer overjacket
  • Interlocking armor can be easily removed leaving an intact inner cable
  • Greater flexibility than corrugated steel armored (CST) cables
  • Ideal for locations that require conduit for cable protection
  • Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments

Features

  • UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
  • Fluorpolymer inner and outer jackets
  • Cable materials are Indoor/Outdoor UL-Listed OFCP and also UV, water, chemical, and fungus resistant
  • Jacket is highly chemical resistant for installation in harsh industrial environments
  • High performance tight-buffered coating on each fiber for environmental and mechanical protection
  • 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
  • Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
  • Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments

Characteristics

Characteristic Plenum (Indoor/Outdoor)
Operating Temp -40°C to +85°C
Storage Temp -40°C to +85°C
Install Temp 0°C to +60°C
Flame Retardancy UL Listed Type OFCP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232)
Crush Resist 650 N/cm
Impact Resist 20 impacts
Flex Resist 25 cycles
Jacket Type K

Standards

OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:

  • ANSI/NFPA 262
  • ICEA-S-83-596
  • UL 1651

Specifications

ILA Plenum ("K" jacket)

Tensile Load Minimum Bend Radius
Fiber Count Part Number Part Number Configurator Diameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
2 DX002K***9*PI6 13.1
(0.52)
175.0
(118.0)
1,350
(300)
400
(90)
26.2
(10.3)
19.7
(7.8)
4 DX004K***9*PI6 13.1
(0.52)
175.0
(118.0)
1,350
(300)
400
(90)
26.2
(10.3)
19.7
(7.8)
6 DX006K***9*PI6 13.1
(0.52)
175.0
(118.0)
1,350
(300)
400
(90)
26.2
(10.3)
19.7
(7.8)
12 DX012K***9*PI6 14.1
(0.56)
209.0
(140.0)
1,350
(300)
400
(90)
28.2
(11.1)
21.2
(8.3)
18 DX018K***9*PI6 14.1
(0.56)
209.0
(140.0)
1,350
(300)
400
(90)
28.2
(11.1)
21.2
(8.3)
24 DX024K***9*PI6 16.1
(0.63)
264.0
(177.0)
1,350
(300)
400
(90)
32.2
(12.7)
24.2
(9.5)
36 DX036K***9*PI6 16.1
(0.63)
273.0
(183.0)
1,350
(300)
400
(90)
32.2
(12.7)
24.2
(9.5)
48 DX048K***9*PI6 17.7
(0.70)
320.0
(215.0)
1,350
(300)
400
(90)
35.4
(13.9)
26.6
(10.5)
72 DX072K***9*PI6 20.7
(0.81)
456.0
(306.0)
1,350
(300)
400
(90)
41.4
(16.3)
31.1
(12.2)
96 DX096K***9*PI6 22.3
(0.88)
518.0
(348.0)
1,350
(300)
400
(90)
44.6
(17.6)
33.5
(13.2)